Pass Your Alaska Electrical License Exam!

When you need to pass your Alaska Electrical Exam, order this course!

Licenses issued by examination.

Our online electrical license course thoroughly prepares you to pass your selected Alaska Administrator Electrical or Electrical Certificate of Fitness exam.

Clear

$199.00

SKU: N/A Category:

Get your Alaska Electrical License and work as an electrician in Alaska.

Get Licensed! Alaska law requires that all electrical administrators and journeyman electricians must be licensed if performing electrical work.

The sooner you start the sooner you pass.

Get your Alaska Electrical License.

If you are taking the Alaska Electrical Administrator or one of the Journeyman Electrician Exams this course will teach you how to pass your exam the first time you test.

How? Because TLC Works! Our programs are among the most successful, comprehensive, and affordable training and exam preparation programs available anywhere.

The key to your success while using our program is a 22-lesson breakdown of our curriculum, designed to maximize your learning & retention potential. If you follow our curriculum, you WILL PASS your exam!

We provide a comprehensive strategy to pass either of the Alaska Electrical exams, by teaching you how to “navigate” the 2017 NEC. You will quickly become an expert at finding the answers to exam questions rapidly and accurately.

Why choose TLC to help pass the electrical exam? Because your time is too valuable to choose anyone else!


Five Reasons to Enlist TLC to Ensure you Pass your Alaska Electrical Exam.

  1. TLC has fifteen years of experience educating electricians on how to navigate the code and pass state-required electrician tests. We are experts at helping electricians pass the electrical exam!
  2. A+ Rated with the BBB. Our Program Works, we have never received a complaint. Check us out! 
  3. Our eTextbooks and online study center contain over 1300 multiple choice questions taken directly from the 2017 NEC (the basis of the Alaska State test), as well as dozens of timed simulated full-length practice exams.
  4. We guarantee that YOU WILL PASS YOUR EXAM! If you don’t pass your Alaska Electrical exam after two attempts, We offer a full refund.
  5. We have a 98% Pass Rate! Our students pass the exam. In fact, out of the 3000+ electricians that have used our study courses, less than 50 failed to pass on the first try.

Our students pass, we guarantee it! Our students enjoy a 98% pass rate!

Consultants are available at 866-685-8564 – Mon-Fri 7 am to 10 pm pst to answer any of your questions.

Course Breakdown – This course covers the Alaska Electrical exam.

Study at home! Don’t waste time commuting to a classroom when you can study conveniently in your home or office. Our program is a proven, reliable, and affordable way to pass the Alaska Electrical exam.

Each student has access to the following online e-books and online study center for one year.


Basic Electrical Theory – eBook

Includes
  • AC Current
  • Simple AC Current Calculations
  • AC Phase
  • Phase Rotation
  • Single-Phase Power Systems
  • Three-Phase Power Systems
  • Three-Phase Y and Delta Configurations
  • Measurements AC Magnitude
  • Power in Resistive and Reactive AC Circuits
  • Calculating Power Factor
  • Practical Power Factor Correction
  • Kirchhoff’s law.

Supplemental Study Guides – eBook

Includes
  • Ohms Law Tutorial
  • Prints & Specifications Tutorial
    • Wire Color Codes
    • Electronic Symbols
    • Electrical Diagrams
  • Digital Multimeters
  • 29 CFR Part 1926 Safety & Health Regulations for Construction Overview

Navigating the 2013 NFPA-72 – eBook (Administrator Courses Only)

Includes
  • How to quickly reference the NFPA
  • Code reference speed drills
  • Table of Contents
    • Layout and structure of the codebook
  • How to use the Index
  • TLC System for answering test questions
    • Keyword Identification – How to identify the subject of a question
    • Example questions are broken down for your review
    • Practice questions with answers fully mapped out

Navigating the 2017 NEC – eBook

Includes
  • How to quickly reference the NEC
  • Code reference speed drills
  • Table of Contents
    • Layout and structure of the codebook
  • How to use the Index
  • TLC System for answering test questions
    • Keyword Identification – How to identify the subject of a question
    • Example questions are broken down for your review
    • Practice questions with answers fully mapped out

Online Study Center  –  Study Questions and Practice Exams

Access Study Questions and Simulated Exams From Any Device With Internet Access!

These questions provide the framework for you to practice locating the answers to exam questions through the use of the 2017 NEC Codebook. The process of constantly utilizing the codebook to answer practice questions will build up the speed and code knowledge you need to successfully pass your electrical exam.

Four modes of study!

  • Study Mode: This covers over 1300 Alaska electrical exam questions and answers within our course.  (Organized as Question – Answer – Code Location)
    • General Trade Knowledge Questions (General electrical questions not in the code)
    • Blueprint Reading Questions
    • Calculation Questions (Load Calculations, Conduit Fill, etc.)
    • 2017 NEC Code Questions
  • Flashcard Mode: Online Virtual Flashcards provide randomized access to our entire question set, an ideal setting to practice exam questions. (Organized as Question – Answer – Code Location)
  • Chapter Tests: Provide real-time feedback on each section of our study materials, enabling you to concentrate on sections that need improvement.
  • Simulated Final Exams: Simulates the taking of your Electrical exam.
    • Full length (Exact  number of questions)
    • Timed (Exact same amount of time allowed)
    • Randomized (Questions are randomized, all exams are unique)
    • Properly Balanced (Balanced according to the Candidate Information Bulletin guaranteeing a realistic exam simulation)

Take as many simulated final exams as you want! (These exams help you to gain the knowledge, speed, and confidence needed to pass your electrical exam effortlessly)


One year online access: Full access membership to our online study center. Experience the convenience of learning at home, or in office, saving valuable travel time to an in-person course.

Our program is a reliable, affordable way to prepare for the Alaska Electrical Exam. 

This program requires a copy of the 2017 (NEC) National Electric Code. If you do not own a copy of the codebook, you should acquire one immediately!

Frequently Asked Questions

Common exam questions answered here! Please check with your State for current information. Licensing requirements change, and our site may not have been updated to reflect those changes.

Frequently Asked Questions


QUESTION: Who is required to have an Alaska Electrical License?

ANSWER: All individuals engaged as Electrical Administrators, and all Journeyman Electricians performing work, must be licensed by the Alaska Business and Professional Licensing Department or  Alaska Department of Labor and Workforce Development.


QUESTION: How much experience is required by the State of Alaska to become a licensed Electrical Administrator?

ANSWER: This depends on the category in which you are applying and can be found on the Electrical Administrators Application Stating on Page 3.


QUESTION: How much experience is required by the State of Alaska to become a licensed Journeyman Electrician?

ANSWER: This depends on the Certificate of Fitness you are applying for; these requirements are listed on page 3 of the Application for Certificate of Fitness


QUESTION: How do I sign up for an Electrical Administrator License exam?

ANSWER: All candidates must fill out and submit an Electrical Administrator License application form to the Alaska Professional Licensing Contractor Licensing Section for approval to sit the exam.


QUESTION: How do I sign up for a Certificate of Fitness Journeyman Electrical License exam?

ANSWER: All candidates must fill out and submit an application for the Certificate of Fitness for Journeyman Electrical application form to the Alaska Department of Labor Mechanical Inspection Department for approval to sit the exam.


QUESTION: What content is included in the exam, how many questions are there, and how much time do I have to complete it?

ANSWER:

Administrator Exam: It depends on which Administrator Exam you are taking; license exams differ in length. Please refer to the Alaska Administrators Exam PSI Candidate Information Bulletin.

Certificate of Fitness Exam: It depends on which Certificate of Fitness Exam you are taking; license exams differ in number of questions. Each exam you are given four hours.

Residential Journeyman:  Is 50 questions ( 25 true or false & 25 multiple choice)

Journeyman: Is 100 questions ( 50 true or false & 50 multiple choice)


QUESTION: Why study TLC’s course if the Electrical Administrator and Journeyman Electrical Certificate of Fitness exams are open book? 

ANSWER: The electrical license exam is complex. It can require at least a month of study and preparation to pass.

The 2017 NEC is a publication containing over 800 pages of complex code. Through TLC’s course, locating the correct answer within the time allowed during the exam will be mastered.

TLC prepares you to successfully pass your exam by providing extensive instruction on the structure of the code. Each subject appearing in your Alaska Electrical Exams is broadly covered.


QUESTION: Why is a copy of the 2017 NEC required for this course?

ANSWER: Alaska Electrical exams are based on the 2017 NEC. TLC’s proven companion course will guide you through frequent references to critical code. Preparing you for your upcoming license exam.


QUESTION: What can I bring into the testing center?

ANSWER: Approved References for the administrator exams are addressed in the Candidate Information Bulletin.


QUESTION: Where do I go to take my Electrical Administrator exam?

ANSWER: All exams are managed and administrated at a third-party testing center. For details and a list of test centers in your area, contact PSI Services, Inc Or telephone them at (855) 746-8173 to register. For a complete listing of Alaska’s testing sites, please refer to the Candidate Information Bulletin


QUESTION: Where do I go to take my Electrical Certificate of Fitness exam?

ANSWER: Are given by appointment only. Call the Mechanical Inspection office to schedule testing in Anchorage, Fairbanks, or Juneau.

Note: Contact the Anchorage office for information on testing in other selected Alaska communities. (907) 269-4925

Alaska Electrical Exam Applications

Don’t delay start today. Fill out and submit your applications ASAP

 

 

Complete the appropriate application and submit it to the Alaska Electrical Application ASAP.


General Information Links:


Electrician Applications:

Certificate of Fitness Renewal Form

Free Alaska Electrical Practice Exam

Pass this 50 question free Alaska Electrical exam, learn where you stand! These free electrician exam practice questions are very similar to the ones on the Alaska Electrical exam.

IF YOU ANSWER 40+ PRACTICE QUESTIONS CORRECTLY YOU ARE IN PRETTY GOOD SHAPE. However, if you miss ten or more questions you risk failing your Alaska Electrical exam.

 

Of the following output characteristics, which is NOT required to be compatible to the output of a generator or other electric power production source operating in parallel with an electrical supply system?

Correct! Wrong!

What is the MINIMUM bending radius for a power and control tray cable with a metallic shielding?

Correct! Wrong!

The working space in front of fire or electrical equipment may be used to store

Correct! Wrong!

Surface nonmetallic raceways that have limited smoke-producing characteristics shall be

Correct! Wrong!

What is the MAXIMUM number of branch circuit conductors permitted in a recognized wiring method between luminaries connected together on a single phase 120/240 volt system?

Correct! Wrong!

In what location are disconnecting means NOT required for individual luminaries with fluorescent double ended lamps and ballasts?

Correct! Wrong!

The top of a 12 inch deep wall cabinet, installed in a room with electric space heating cables embedded in the ceiling, shall be below the ceiling no less than

Correct! Wrong!

Non-heating leads from fixed outdoor electric deicing and snow melting embedded resistance heating panels shall be permitted to be protected by

Correct! Wrong!

What is the MAXIMUM ac control voltage to ground for permanent amusement attractions?

Correct! Wrong!

The site-isolating device installed at the distribution point for agricultural buildings shall be

Correct! Wrong!

A MAXIMUM continuous load on an overcurrent device is limited to 90 percent of the device rating. If the protective device is rated 80A, what is the MAXIMUM continuous load permitted?

Correct! Wrong!

How many sets of 5-wire feeders sharing the same common neutral are allowed?

Correct! Wrong!

What type of receptacles are permitted on a 40-amp branch circuit with multiple receptacles?

What type of receptacles are permitted on a 40-amp branch circuit with multiple receptacles?
Show hint
Correct! Wrong!

The equipment grounding conductor inside an underground feeder and branch-circuit cable is

Correct! Wrong!

Which National Electrical Code article covers telephone, telegraph, outside wiring for fire and burglar alarm systems and similar central station systems?

Correct! Wrong!

At what distance from entering the building must the metal sheath of communication cable be grounded or interrupted?

Correct! Wrong!

Multiwire branch circuits supply only line to neutral loads EXCEPT where they supply only one utilization equipment or_________

Correct! Wrong!

In a dwelling unit garage, GFCI protection of 15 and 20 ampere receptacles are required for_________

Correct! Wrong!

Where a counter-mounted cooking unit is mounted in a corner, the space behind the unit is exempt from wall countertop receptacle spacing requirements when the measurement from the back of the unit to the corner of the wall is less than_________

Correct! Wrong!

When are conductors required to be protected?

Correct! Wrong!

What component permits voltage to be stepped up or down?

Correct! Wrong!

Where required, mitigating measures shall be implemented for the period that a system is impaired, only when acceptable to the

Correct! Wrong!

After installation, when shall a central station be checked for sensitivity?

Correct! Wrong!

What is a Tactile Notification Appliance?

Correct! Wrong!

Smoke detectors with control output functions shall be verified that the control capability shall remain operable even if the signaling line circuit is in alarm state or_________

Correct! Wrong!

What best describes the purpose of inspection, testing and maintenance of a fire alarm system?

Correct! Wrong!

One method of defining circuit integrity cable is by establishing a MINIMUM fire resistance rating of how many hours?

Correct! Wrong!

Which of the following methods is acceptable to show the location of the detector and the area protected on a remote alarm indicator?

Correct! Wrong!

A circuit that contains both series and parallel elements is known as

Correct! Wrong!

What is the permitted location rule for a supplementary visible notification appliance?

Correct! Wrong!

In new construction, luminaries installed within 1.5 meters (5 feet) of the edge of the water or over a pool, fountain, or similar body of water must be mounted a vertical distance above the maximum water level of no less than___________

Correct! Wrong!

In Class I Division 1 and 2 locations, flexible cords are

Correct! Wrong!

Without exceptions, Liquidtight Flexible Metal Conduit (LFMC) shall be securely fastened in place by approved means within how many inches of each box, cabinet, conduit body or other conduit termination?

Correct! Wrong!

Electrical metallic tubing is designed to protect and____________

Correct! Wrong!

Flexible metallic tubing is considered which of the following?

Correct! Wrong!

Electrical nonmetallic tubing is used for the installation of which of the following?

Correct! Wrong!

Cord connected luminaries installed in bathtub and shower areas shall NOT have any parts within a zone measured

Correct! Wrong!

When installing surface mount or recessed luminaries in a closet, the lamp must be completely___________

Correct! Wrong!

After installation, outlet boxes must be provided with a cover unless covered by means of a____________

Correct! Wrong!

Where a metal lampholder is connected to a flexible cord, the inlet shall be equipped with an insulated bushing that, if threaded, is NOT smaller than

Correct! Wrong!

Which of the following materials can NOT be used for antennas and their lead-in conductors?

Correct! Wrong!

Type CATVX cables less than how many inches in diameter are permitted to be installed in multi-family dwellings?

Correct! Wrong!

Class 1, Class 2 and Class 3 circuits should be identified at terminal and junction boxes because

Correct! Wrong!

Secondary protectors on circuits exposed to accidental contact with electrical light or power conductors operating at greater than 300 volts to ground are__________

Correct! Wrong!

Driven telecommunication primary protector ground rods to supplement intersystem ground connections should be separated from electrodes of other systems by at LEAST

Correct! Wrong!

Where a roof has a slope of NOT less than 100 mm (4 inches) in 300 mm (12 inches) above roof clearance of a communication cable of NOT less than what distance shall be permitted?

Correct! Wrong!

Class 1 circuit conductors in sizes of 18 American Wire Gauge and 16 American Wire Gauge should be installed as any type EXCEPT

Correct! Wrong!

For Radio and Television distribution equipment, a bonding device intended to provide a termination point for the grounding conductor should comply with all of the following conditions EXCEPT

Correct! Wrong!

All inside conductors associated with the interior installation of transmitting stations should be separated from conductors of any electric light, power or signaling circuits by at least___________

Correct! Wrong!

Where the MAXIMUM span between supports is more than 35 feet, all of the following materials are approved for use as antenna and lead-in conductors for receiving equipment EXCEPT

Correct! Wrong!

What is the purpose of the NEC (National Electrical Code), with regard to the hazards arising from the use of electricity, with regard to persons or property?

Correct! Wrong!

Where does this code not cover the installation of optical fiber cables and raceways, or conductors, equipment and raceways for electrical, signaling, and communications?

Correct! Wrong!

Because limiting the number of circuits on a single enclosure minimizes the effects from a ground fault or short circuit in one circuit, the NEC provides that the number or circuits and wires in a single enclosure be:

Correct! Wrong!

Conductors, based on the ______ °C temperature rating and ampacity as given in Table 310.60(C)(67) through Table 310.60(C)(86), may be terminated unless otherwise identified.

Correct! Wrong!

For equipment rated 1200 amperes or more and over 6 feet wide that contain overcurrent devices, there shall be one entrance to and egress from the required working space not less than ________ inches wide and ________ feet high at each end of the working space.

Correct! Wrong!

Unless they are under __________________, the entrance to any buildings, enclosures, rooms, or vaults with exposed conductors or live parts operating at over 600 volts nominal must be kept locked.

Correct! Wrong!

Access and ______ space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

Correct! Wrong!

In front of electric equipment, the working space width must be at least ______ in., or the width of the equipment, whichever is greater. Also, the working space must have space for doors or hinged panels to open ______ degrees or more.

Correct! Wrong!

A large single panel, frame, or assembly of panels on which are mounted on the face, back, or both, switches, overcurrent and other protective devices, buses, and usually instruments.

Correct! Wrong!

When an installation in concrete slabs or masonry or underground, in direct contact with the earth, is in a location that can be saturated with water or other liquids (vehicle washing areas, for example), or is exposed to weather in an unprotected location, that is known as a:

Correct! Wrong!

A system or circuit conductor that is intentionally grounded.

Correct! Wrong!

What is the definition of Continuous Duty?

Correct! Wrong!

For fixed outdoor electric deicing equipment, the ampacity of branch-circuit conductors and the rating or setting of overcurrent protective devices supplying the equipment shall be a minimum of ______ of the full-load current

Correct! Wrong!

For a one-family dwelling with a 200 ampere, 120/240-volt, single-phase main service panel, supplied with size 2/0 AWG THW copper ungrounded service-entrance conductors in rigid metal conduit (RMC), what is the minimum allowed size of bonding jumper for the service-entrance conduit?

Correct! Wrong!

When a metal well casing is used with a submersible pump, the pump equipment grounding conductor must be ____________ the well casing.

Correct! Wrong!

For a 5-hp, 3-phase, 208-volt motor with 20-ampere rated overload protection and branch-circuit, short-circuit and ground fault protection rated at 30 amperes, what is the minimum required size of grounding conductor?

Correct! Wrong!

How many times may a grounding electrode conductor be spliced, using a listed split-bolt connector?

Correct! Wrong!

What is the minimum size underground installed service-lateral conductors allowed by the NEC, aside from any exceptions?

Correct! Wrong!

When overhead spans of open conductors and open multiconductor cables pass over a roof, the vertical clearance must be at least ______ ft. above the surface. This clearance must be maintained for at least ______ ft. in all directions from the edge of the roof. Exceptions ignored.

Correct! Wrong!

For the servicing of air-conditioning, heating and refrigeration equipment, a 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet must be installed within ______ of the equipment, at an accessible location.

Correct! Wrong!

Other than for supplying ____________ outlets or extension to the area below the floor but not above it, Cellular Concrete Floor Raceways may not be used in commercial garages.

Correct! Wrong!

If a raceway containing power-limited, remote-control, and signaling circuits is where condensation is known to be a problem and is subjected to different temperatures, it is required for the raceway to be filled with a material to prevent the circulation of warm air to a colder section of the raceway, that is approved by the authority having jurisdiction. Explosion-Proof seals:

Correct! Wrong!

For supplying a fixed electric space heating unit with heating elements having a full-load current rating of 125 amperes and a blower motor with a full-load current rating of 2.5 amperes, what is the minimum size 75° C rated copper conductors required?

Correct! Wrong!

Where shall liquidtight flexible metallic conduit (LFMC) not be used?

Correct! Wrong!

What is the maximum distance between supports for standard trade size 2 in. right Schedule 40 polyvinyl chloride conduit (PVC)?

Correct! Wrong!

When RMC threadless connectors and couplings are used with conduit, they must be made tight, and when they are to be buried in concrete or masonry, they must be:

Correct! Wrong!

The maximum percent of FMC conduit interior total area the may be filled if more than 2 conductors are used in the tube is:

Correct! Wrong!

The tightest bend allowed by the NEC for Type NM cable is a radius of how many times the diameter of the cable?

Correct! Wrong!

A factory assembly of one or more insulated conductors with an integral or overall covering of nonmetallic material suitable for direct burial in the earth.

Correct! Wrong!

For an individual branch circuit in a flat conductor cable assembly, what is the maximum ampacity?

Correct! Wrong!

If a pole is over 8 ft. in height, a ____________ terminal must be accessible from a handhole.

Correct! Wrong!

What is required for a control transformer when a 240-volt wye-connected motor gets power from a converted single-phase source, and it is intended to connect a 120/240-volt transformer to control the motor on the load side of the converter?

Correct! Wrong!

What is the full-load running current rating of a 208-volt, 3-phase, 50 hp, squirrel-cage, continuous-duty, AC motor?

Correct! Wrong!

For a branch-circuit where lighting outlets or general-use receptacles are also supplied, what is the maximum percentage of the rating that may not be exceeded by a cord-and-attachment-plug connected room air-conditioner?

Correct! Wrong!

Of the following, which is not a requirement for marking on a transformer’s nameplate?

Correct! Wrong!

Which of the following is a requirement for electrically heated floors in bathrooms, kitchens, and in hydromassage bathtub locations?

Correct! Wrong!

Lighting systems for fountains, pools, spas, and similar locations must be installed __________ or more horizontally from the nearest water’s edge, unless Article 680 permits otherwise.

Correct! Wrong!

On portable generators manufactured before ____________, listed cord sets or adapters incorporating listed GFCI protection are allowed to be used to meet the GFCI requirement.

Correct! Wrong!

Temporary electric power and lighting installations for holiday decorative lighting and similar purposes is allowed for a maximum of:

Correct! Wrong!

Where the available short-circuit current for the battery bank on a PV system exceeds the interrupting or ____________ ratings of the equipment it supplies, a listed current-limiting overcurrent device must be installed.

Correct! Wrong!

Tap conductors on a common dc grounding electrode conductor of a PV system must be sized in compliance with 250.166. The connection between the common grounding electrode and the tap conductor must be such that the common grounding electrode conductor is:___________

Correct! Wrong!

Power-limited fire alarm cable must have a moisture-impervious metal sheath or be listed for the purpose if they are used in what kind of location?

Correct! Wrong!

What must be done with approved ratings, to maintain the fire-resistance rating, to openings around penetrations of raceways for communications and optical fiber cables through fire-resistant-rated ceilings, floors, partitions, and walls?

Correct! Wrong!

When are Class 1 circuit conductor and power-supply conductors are allowed to be in the same cable, enclosure, or raceway?

Correct! Wrong!

It is not required to list or mark community antenna television and radio system coaxial cables if the cable is not more than ______ from where the cable enters the building from the outside to where it is terminated at a grounding block.

Correct! Wrong!

During lightning events, limiting the length of the primary protector grounding conductors for communications circuits assists in reducing voltage between the buildings communications systems and:___________

Correct! Wrong!

What type of protection is needed for the grounding electrode conductor for an antenna if it is subject to physical damage?

Correct! Wrong!

What is the maximum cross-sectional value that conduit nipples under 24 inches long may be filled?

Correct! Wrong!

If more than 2 conductors are used in a tube of EMT conduit, total interior area that can be filled is no more than ________ percent.

Correct! Wrong!

Given the following information, what is the maximum approximate distance a single-phase, 240-volt, 42 ampere load can be located from a panelboard? * copper conductors – K = 12.9 * size 8 AWG THWN/THHN conductors are used * Limit voltage drop to 3%

Correct! Wrong!

100 Question Timed Free Electrician Certification Exam