Get your Nevada Residential Electrician, Journeyman Electrician, or Master Electrician License.

Get Certified! Nevada law requires that all Residential, Journeyman, or Master electricians be licensed to perform electrical work. If you do not possess a current Nevada Electrician license, you are working illegally.

Get Certified NOW!  If you do not possess a current Nevada Electrician license, you may be working illegally. Complete the appropriate application and submit it to the Nevada Construction Industries Board ASAP. Applications are reviewed quarterly. Pass the Nevada Journeyman or Master Electrician exam and work in Nevada legally.


Get your Nevada Residential, Journeyman, or Master Electrician Licence.

IF YOU ARE TAKING THE FOLLOWING NEVADA ELECTRICIAN EXAMS, THIS COURSE WILL TEACH YOU HOW TO PASS YOUR EXAM THE FIRST TIME YOU TEST. THE G16 RESIDENTIAL ELECTRICIAN EXAM. THE G17 JOURNEYMAN ELECTRICIAN EXAM. OR THE G18 MASTER ELECTRICIAN EXAM

How? Because TLC Works: Our programs are among the most successful, comprehensive, and affordable training and exam preparation programs available anywhere.

The Master key to your success while using our program is “The Plan:” A 22-lesson breakdown of our entire curriculum, designed to maximize your learning & retention potential. If you follow our curriculum, you WILL PASS your exam!

We provide a comprehensive strategy to pass the ICC Nevada Electrical Licence exam, as well as how to “navigate” the 2017 NEC. You will quickly become an expert at finding the answers to exam questions rapidly and accurately.

Satisfaction is guaranteed! All of our programs have a five day evaluation period. If you don’t see the value in what you’ve purchased, send it back for a full refund.

Why choose ECC? for your electrical certification exam? Because your time is too valuable to do anything else!


Five Reasons to Enlist ECC to help you PASS YOUR NEVADA JOURNEYMAN ELECTRICIAN EXAM.

  1. We have fifteen years of experience teaching electricians how to pass their Electrical Certification Exam. We are experts in teaching you how to navigate the Code. We have been helping electricians pass this test since 2005. We know how to help you pass your exam and get you certified!
  2. A+ Rated with the BBB. OUR PROGRAM WORKS. WE HAVE NEVER RECEIVED A COMPLAINT!
  3. Our textbooks and online study center contain over 1200 multiple choice questions taken directly from the 2017 NEC (the basis of the Nevada State test), as well as numerous full-length practice exams.
  4. We guarantee that YOU WILL PASS YOUR EXAM! TLC was the first 32 Hour ONLINE continuing education school in California. We are the ONLY one that offers both Certification Exam Test Preparation and Online Continuing Education.
  5. We have a 98% Pass Rate! Our students pass the exam. In fact, out of the 3000+ electricians that have used our study courses, less than 50 failed to pass on the first try.

OUR STUDENTS PASS, we guarantee it! Our students enjoy a 98%+ pass rate!

Consultants are available at 866-685-8564 – Mon-Fri 7 am to 10 pm pst to answer questions & lend assistance.

Course Breakdown – Nevada Residential Electrician, Journeyman Electrician, or Master Electrician Exam

Study and test at home! Don’t waste time commuting to a classroom when you can study conveniently in your home or office. Our program is a proven, reliable, and affordable way to pass the Nevada Electrician exam.

This course covers the Nevada Journeyman Electrician exam.

Don’t waste time commuting to a classroom when you can study conveniently in your home or office. Our program is a reliable, affordable way to pass the Nevada Journeyman Electrician Certification exam.


Basic Electrical Theory – eBook

 

Includes
    • AC Current
    • Simple AC Current Calculations
    • AC Phase
    • Phase Rotation
    • Single-Phase Power Systems
    • Three-Phase Power Systems
    • Three-Phase Y and Delta Configurations
    • Measurements AC Magnitude
    • Power in Resistive and Reactive AC Circuits
    • Calculating Power Factor
    • Practical Power Factor Correction
    • Kirchhoff’s law.

Supplemental Study eBook

Includes
    • Ohms Law Tutorial
    • Prints & Specifications Tutorial
      • Wire Color Codes
      • Electronic Symbols
      • Electrical Diagrams
    • Digital Multimeters

Navigating the 2017 NEC eBook

Includes
    • How to quickly reference the NEC
    • Code reference speed drills
    • Table of Contents
      • Layout and structure of the codebook
    • How to use the Index
    • TLC System for answering test questions
      • Keyword Identification – How to identify the subject of a question
      • Example questions are broken down for your review
      • Practice questions with answers fully mapped out

ONLINE STUDY CENTER – Practice Exams & Study Questions

Book Study Mode | Flash Card Study Mode | Chapter Test Mode | Exam Simulation Mode:

Access Study Questions & Simulated Exams from any device with internet access! Online features include 1200+ practice questions, virtual flashcards, chapter exams, & unlimited mock final exams.

These questions exist to provide a framework for you to practice locating the answers to questions through use of your NEC Codebook. It is this process of constantly utilizing the code to answer practice questions that will build up the speed and code knowledge to successfully pass your electrical exam.

Four Modes of study!

  • STUDY MODE This mode covers all Alabama electrical exam questions and answers within our course.  (Organized as Question – Answer – Code Location.)

Included in this mode of study are;

  • General Trade Knowledge Questions (General electrical questions not in the code)
  • Blueprint Reading Questions
  • Calculation Questions (Load Calculations, Conduit Fill, etc.)
  • 2017 NEC Code Questions

FLASHCARD MODE: Online Virtual Flashcards provide individual randomized questions. This mode of study presents access to our entire question set and is an ideal setting to practice answering randomized exam questions. (Organized as Question – Answer – Code Location.

CHAPTER TESTS: Verify your understanding of each section of our structured study questions. (Practice tests provide real-time feedback on each section of our study materials and enable you to concentrate on those sections most needing improvement.

SIMULATED FINAL EXAM: Final exams simulate the experience of taking your actual electrician exam.

Simulated Finals Are:

  • Full length (Exact same number of questions as the Master Electrician exam)
  • Timed (Exact same amount of time allowed as the Master Electrician exam)
  • Randomized (Questions are assigned randomly; all exams are unique.)
  • Properly Balanced (All questions are balanced according to the Candidate Information Bulletin to guarantee a realistic exam simulation)

Take as Many Timed Final Exams as you Want! (Practice exams help you rapidly gain confidence and knowledge to pass your Electrical Exam effortlessly.)


ONE YEAR ONLINE ACCESS: 1-year full access membership to our Online Study Center. Conveniently study in your home or office without wasting valuable time commuting to distant classes.

Our program is a reliable and affordable way to prepare for your Alabama Electrician Exam while at home and online.

 

THIS PROGRAM REQUIRES YOU TO HAVE A COPY OF THE 2017 (NEC) NATIONAL ELECTRIC CODE. IF YOU DO NOT OWN A COPY OF THE CODEBOOK, YOU SHOULD ACQUIRE ONE IMMEDIATELY.

Frequently Asked Questions

Common exam questions answered here! Please check with your State Board for current information. Licensing requirements change, and our site may not have been updated to reflect those changes.

Frequently Asked Questions

Please check with your State or Local Board for current information. Licensing requirements change and our site may not have been updated to reflect those changes.


QUESTION: Who is required to have a Nevada Journeyman Electrician license?

ANSWER: The Nevada Construction Industries Board must license any individual who is engaged in the electrical contracting business or is performing work as an Electrical Contractor or Electrical Journeyman.


QUESTION: What are the qualifications required for taking the exam?

Requirements are typically as follows for the following Electrical Licences.

RESIDENTIAL ELECTRICIAN: must typically demonstrate a minimum of 4,000 Verifiable hours on the job experience in electrical construction work while employed by an electrical contractor and registered as an apprentice under the direct supervision of a licensed journeyman or licensed contractor.

JOURNEYMAN ELECTRICIAN: 8,000 Verifiable hours on the job experience in electrical construction work while employed by an electrical contractor and registered as an apprentice under the direct supervision of a licensed journeyman or licensed contractor.

MASTER ELECTRICIAN: 4,000 Verifiable hours on the job experience in electrical construction work while employed by an electrical contractor and registered as an apprentice under the direct supervision of a licensed journeyman or licensed contractor. 1,000 hours may be satisfied by formal electrical education. Educational Experience must be actual classroom hours verified with a transcript.


QUESTION: How do I sign up for the exam?

ANSWER: You must fill out and submit the Journeyman Application for Electrical Licensure form to the Nevada Construction Industries Board to be approved to take the exam.

The exam is administered by a third-party testing center, ICC International Code Council. You can contact PSI with any questions at (800) 733-9267 Hours of operation are 9 am to 5 pm Mon-Fri, (Pacific Time)


QUESTION: How long is the exam?

ANSWER: The G18 Residential Electrician exam consists of 60 multiple-choice questions.  Test takers have 4:00 hours to complete the exam and must score 70% or greater to pass. The exam is open-book with authorized materials and is computer-based.

The exam covers the following subjects:

  • General Knowledge 12%
  • Services and Service Equipment 22%
  • Feeders 13%
  • Branch Circuits and Conductors 25%
  • Wiring Methods and Materials 13%
  • Equipment and Devices 8%
  • Special Occupancies, Equipment, and Conditions 7%

ANSWER: The G17 Journeyman Electrician exam consists of 80 multiple-choice questions. Test takers have 3:00 hours to complete the exam and must score 70% or greater to pass. The exam is open-book with authorized materials and is computer-based.

The exam covers the following subjects:

  • General Knowledge 6%
  • Services and Service Equipment 11%
  • Feeders 4%
  • Branch Circuits and Conductors 19%
  • Wiring Methods and Materials 26%
  • Equipment and Devices 13%
  • Control Devices 4%
  • Motors and Generators 6%
  • Special Occupancies, Equipment, and Conditions 11%

ANSWER: The G16 Master Electrician exam consists of 100 multiple-choice questions. Test takers have 5:00 hours to complete the exam and must score 75% or greater to pass. The exam is open-book with authorized materials and is computer-based.

The exam covers the following subjects:

  • General Knowledge and Plan Reading 12%
  • Services and Service Equipment 16%
  • Feeders 4%
  • Branch Circuits and Conductors 16%
  • Wiring Methods and Materials 19%
  • Equipment and Devices 10%
  • Control Devices 3%
  • Motors and Generators 8%
  • Special Occupancies, Equipment, and Conditions 12%

QUESTION: Why should someone study this course if the Residential, Journeyman and Master Electrician license exam is an open-book test?

ANSWER: The electrical certification test is a very challenging exam and usually requires a month or more of preparation to pass.

The 2017 NEC is a large and complex publication containing over 1000 pages of code. It is challenging to locate each correct article and answer in the time allowed during the exam without thorough preparation.

Our course is designed to familiarize you with the 2017 NEC. You will know precisely how to find the correct answers in the code when you take your exam.

We prepare you to successfully pass your exam by providing extensive knowledge of the structure of the code and by thoroughly covering each subject appearing on your Nevada Electrical License Exam.


QUESTION: Why is a copy of the 2017 NEC required by this course?

ANSWER: The Nevada Journeyman Electrician License Exam is based on the 2017 NEC. This course is an excellent study companion to the 2017 NEC. This course makes frequent references to code sections and guides you through the exam topics.

The Electrical License Exam is an open-book code exam. To pass, you must continuously reference the 2017 National Electrical Code.

The following codes and books are permitted to be brought into the testing center.

  • NFPA 70 – National Electrical Code, 2017 Edition.
  • Ugly’s Electrical References, George V. Hart, (any edition may be used)

QUESTION: What else can I bring into the testing center?

ANSWER:

  • Pencils. (Paper/pencil testing only)
  • Calculator. Only simple 4-function calculators are permitted. PDAs, cell phones, or other special calculators (i.e., ElectriCalc, etc.) are not allowed.

Approved References are addressed in the Candidate Information Bulletin.


QUESTION: Where do I go to take my exam?

ANSWER: With ICC PRONTO you can take the exam at home on your Computer!

Nevada Electrician Exam Applications

Don’t delay start today. Fill out and submit your applications ASAP, The Nevada Board of Electrical Examiners  can take six to eight weeks to approve your application and authorize you to take your exam

Nevada Residential, Journeyman & Master Electrician Application:

  • License Renewal Application.

General Information Links:

  • Electrician Licensee Search Tool:
    CHECK ELECTRICIAN CERTIFICATION STATUS

Free Nevada Electrician Practice Exam

Pass this 50 question free Nevada Electrician exam, learn where you stand! These free electrician exam practice questions are very similar to the ones on the actual Nevada electrician exam.

Free Electrical Certification Exam Practice Questions:

Pass this free 50 question Electrical Certification exam to know where you stand! These electrical certification practice questions are similar to the ones you will encounter when taking your actual Nevada Electrical journeyman exam

If you readily answer 40 or more of these practice questions correctly, congratulations, you are in pretty good shape.
However, if you miss ten or more questions, then you are in danger of failing your electrical certification exam Exam.

Of the following output characteristics, which is NOT required to be compatible to the output of a generator or other electric power production source operating in parallel with an electrical supply system?

Correct! Wrong!

What is the MINIMUM bending radius for a power and control tray cable with a metallic shielding?

Correct! Wrong!

The working space in front of fire or electrical equipment may be used to store

Correct! Wrong!

Surface nonmetallic raceways that have limited smoke-producing characteristics shall be

Correct! Wrong!

What is the MAXIMUM number of branch circuit conductors permitted in a recognized wiring method between luminaries connected together on a single phase 120/240 volt system?

Correct! Wrong!

In what location are disconnecting means NOT required for individual luminaries with fluorescent double ended lamps and ballasts?

Correct! Wrong!

The top of a 12 inch deep wall cabinet, installed in a room with electric space heating cables embedded in the ceiling, shall be below the ceiling no less than

Correct! Wrong!

Non-heating leads from fixed outdoor electric deicing and snow melting embedded resistance heating panels shall be permitted to be protected by

Correct! Wrong!

What is the MAXIMUM ac control voltage to ground for permanent amusement attractions?

Correct! Wrong!

The site-isolating device installed at the distribution point for agricultural buildings shall be

Correct! Wrong!

A MAXIMUM continuous load on an overcurrent device is limited to 90 percent of the device rating. If the protective device is rated 80A, what is the MAXIMUM continuous load permitted?

Correct! Wrong!

How many sets of 5-wire feeders sharing the same common neutral are allowed?

Correct! Wrong!

What type of receptacles are permitted on a 40-amp branch circuit with multiple receptacles?

What type of receptacles are permitted on a 40-amp branch circuit with multiple receptacles?
Show hint
Correct! Wrong!

The equipment grounding conductor inside an underground feeder and branch-circuit cable is

Correct! Wrong!

Which National Electrical Code article covers telephone, telegraph, outside wiring for fire and burglar alarm systems and similar central station systems?

Correct! Wrong!

At what distance from entering the building must the metal sheath of communication cable be grounded or interrupted?

Correct! Wrong!

Multiwire branch circuits supply only line to neutral loads EXCEPT where they supply only one utilization equipment or_________

Correct! Wrong!

In a dwelling unit garage, GFCI protection of 15 and 20 ampere receptacles are required for_________

Correct! Wrong!

Where a counter-mounted cooking unit is mounted in a corner, the space behind the unit is exempt from wall countertop receptacle spacing requirements when the measurement from the back of the unit to the corner of the wall is less than_________

Correct! Wrong!

When are conductors required to be protected?

Correct! Wrong!

What component permits voltage to be stepped up or down?

Correct! Wrong!

Where required, mitigating measures shall be implemented for the period that a system is impaired, only when acceptable to the

Correct! Wrong!

After installation, when shall a central station be checked for sensitivity?

Correct! Wrong!

What is a Tactile Notification Appliance?

Correct! Wrong!

Smoke detectors with control output functions shall be verified that the control capability shall remain operable even if the signaling line circuit is in alarm state or_________

Correct! Wrong!

What best describes the purpose of inspection, testing and maintenance of a fire alarm system?

Correct! Wrong!

One method of defining circuit integrity cable is by establishing a MINIMUM fire resistance rating of how many hours?

Correct! Wrong!

Which of the following methods is acceptable to show the location of the detector and the area protected on a remote alarm indicator?

Correct! Wrong!

A circuit that contains both series and parallel elements is known as

Correct! Wrong!

What is the permitted location rule for a supplementary visible notification appliance?

Correct! Wrong!

In new construction, luminaries installed within 1.5 meters (5 feet) of the edge of the water or over a pool, fountain, or similar body of water must be mounted a vertical distance above the maximum water level of no less than___________

Correct! Wrong!

In Class I Division 1 and 2 locations, flexible cords are

Correct! Wrong!

Without exceptions, Liquidtight Flexible Metal Conduit (LFMC) shall be securely fastened in place by approved means within how many inches of each box, cabinet, conduit body or other conduit termination?

Correct! Wrong!

Electrical metallic tubing is designed to protect and____________

Correct! Wrong!

Flexible metallic tubing is considered which of the following?

Correct! Wrong!

Electrical nonmetallic tubing is used for the installation of which of the following?

Correct! Wrong!

Cord connected luminaries installed in bathtub and shower areas shall NOT have any parts within a zone measured

Correct! Wrong!

When installing surface mount or recessed luminaries in a closet, the lamp must be completely___________

Correct! Wrong!

After installation, outlet boxes must be provided with a cover unless covered by means of a____________

Correct! Wrong!

Where a metal lampholder is connected to a flexible cord, the inlet shall be equipped with an insulated bushing that, if threaded, is NOT smaller than

Correct! Wrong!

Which of the following materials can NOT be used for antennas and their lead-in conductors?

Correct! Wrong!

Type CATVX cables less than how many inches in diameter are permitted to be installed in multi-family dwellings?

Correct! Wrong!

Class 1, Class 2 and Class 3 circuits should be identified at terminal and junction boxes because

Correct! Wrong!

Secondary protectors on circuits exposed to accidental contact with electrical light or power conductors operating at greater than 300 volts to ground are__________

Correct! Wrong!

Driven telecommunication primary protector ground rods to supplement intersystem ground connections should be separated from electrodes of other systems by at LEAST

Correct! Wrong!

Where a roof has a slope of NOT less than 100 mm (4 inches) in 300 mm (12 inches) above roof clearance of a communication cable of NOT less than what distance shall be permitted?

Correct! Wrong!

Class 1 circuit conductors in sizes of 18 American Wire Gauge and 16 American Wire Gauge should be installed as any type EXCEPT

Correct! Wrong!

For Radio and Television distribution equipment, a bonding device intended to provide a termination point for the grounding conductor should comply with all of the following conditions EXCEPT

Correct! Wrong!

All inside conductors associated with the interior installation of transmitting stations should be separated from conductors of any electric light, power or signaling circuits by at least___________

Correct! Wrong!

Where the MAXIMUM span between supports is more than 35 feet, all of the following materials are approved for use as antenna and lead-in conductors for receiving equipment EXCEPT

Correct! Wrong!

What is the purpose of the NEC (National Electrical Code), with regard to the hazards arising from the use of electricity, with regard to persons or property?

Correct! Wrong!

Where does this code not cover the installation of optical fiber cables and raceways, or conductors, equipment and raceways for electrical, signaling, and communications?

Correct! Wrong!

Because limiting the number of circuits on a single enclosure minimizes the effects from a ground fault or short circuit in one circuit, the NEC provides that the number or circuits and wires in a single enclosure be:

Correct! Wrong!

Conductors, based on the ______ °C temperature rating and ampacity as given in Table 310.60(C)(67) through Table 310.60(C)(86), may be terminated unless otherwise identified.

Correct! Wrong!

For equipment rated 1200 amperes or more and over 6 feet wide that contain overcurrent devices, there shall be one entrance to and egress from the required working space not less than ________ inches wide and ________ feet high at each end of the working space.

Correct! Wrong!

Unless they are under __________________, the entrance to any buildings, enclosures, rooms, or vaults with exposed conductors or live parts operating at over 600 volts nominal must be kept locked.

Correct! Wrong!

Access and ______ space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.

Correct! Wrong!

In front of electric equipment, the working space width must be at least ______ in., or the width of the equipment, whichever is greater. Also, the working space must have space for doors or hinged panels to open ______ degrees or more.

Correct! Wrong!

A large single panel, frame, or assembly of panels on which are mounted on the face, back, or both, switches, overcurrent and other protective devices, buses, and usually instruments.

Correct! Wrong!

When an installation in concrete slabs or masonry or underground, in direct contact with the earth, is in a location that can be saturated with water or other liquids (vehicle washing areas, for example), or is exposed to weather in an unprotected location, that is known as a:

Correct! Wrong!

A system or circuit conductor that is intentionally grounded.

Correct! Wrong!

What is the definition of Continuous Duty?

Correct! Wrong!

For fixed outdoor electric deicing equipment, the ampacity of branch-circuit conductors and the rating or setting of overcurrent protective devices supplying the equipment shall be a minimum of ______ of the full-load current

Correct! Wrong!

For a one-family dwelling with a 200 ampere, 120/240-volt, single-phase main service panel, supplied with size 2/0 AWG THW copper ungrounded service-entrance conductors in rigid metal conduit (RMC), what is the minimum allowed size of bonding jumper for the service-entrance conduit?

Correct! Wrong!

When a metal well casing is used with a submersible pump, the pump equipment grounding conductor must be ____________ the well casing.

Correct! Wrong!

For a 5-hp, 3-phase, 208-volt motor with 20-ampere rated overload protection and branch-circuit, short-circuit and ground fault protection rated at 30 amperes, what is the minimum required size of grounding conductor?

Correct! Wrong!

How many times may a grounding electrode conductor be spliced, using a listed split-bolt connector?

Correct! Wrong!

What is the minimum size underground installed service-lateral conductors allowed by the NEC, aside from any exceptions?

Correct! Wrong!

When overhead spans of open conductors and open multiconductor cables pass over a roof, the vertical clearance must be at least ______ ft. above the surface. This clearance must be maintained for at least ______ ft. in all directions from the edge of the roof. Exceptions ignored.

Correct! Wrong!

For the servicing of air-conditioning, heating and refrigeration equipment, a 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet must be installed within ______ of the equipment, at an accessible location.

Correct! Wrong!

Other than for supplying ____________ outlets or extension to the area below the floor but not above it, Cellular Concrete Floor Raceways may not be used in commercial garages.

Correct! Wrong!

If a raceway containing power-limited, remote-control, and signaling circuits is where condensation is known to be a problem and is subjected to different temperatures, it is required for the raceway to be filled with a material to prevent the circulation of warm air to a colder section of the raceway, that is approved by the authority having jurisdiction. Explosion-Proof seals:

Correct! Wrong!

For supplying a fixed electric space heating unit with heating elements having a full-load current rating of 125 amperes and a blower motor with a full-load current rating of 2.5 amperes, what is the minimum size 75° C rated copper conductors required?

Correct! Wrong!

Where shall liquidtight flexible metallic conduit (LFMC) not be used?

Correct! Wrong!

What is the maximum distance between supports for standard trade size 2 in. right Schedule 40 polyvinyl chloride conduit (PVC)?

Correct! Wrong!

When RMC threadless connectors and couplings are used with conduit, they must be made tight, and when they are to be buried in concrete or masonry, they must be:

Correct! Wrong!

The maximum percent of FMC conduit interior total area the may be filled if more than 2 conductors are used in the tube is:

Correct! Wrong!

The tightest bend allowed by the NEC for Type NM cable is a radius of how many times the diameter of the cable?

Correct! Wrong!

A factory assembly of one or more insulated conductors with an integral or overall covering of nonmetallic material suitable for direct burial in the earth.

Correct! Wrong!

For an individual branch circuit in a flat conductor cable assembly, what is the maximum ampacity?

Correct! Wrong!

If a pole is over 8 ft. in height, a ____________ terminal must be accessible from a handhole.

Correct! Wrong!

What is required for a control transformer when a 240-volt wye-connected motor gets power from a converted single-phase source, and it is intended to connect a 120/240-volt transformer to control the motor on the load side of the converter?

Correct! Wrong!

What is the full-load running current rating of a 208-volt, 3-phase, 50 hp, squirrel-cage, continuous-duty, AC motor?

Correct! Wrong!

For a branch-circuit where lighting outlets or general-use receptacles are also supplied, what is the maximum percentage of the rating that may not be exceeded by a cord-and-attachment-plug connected room air-conditioner?

Correct! Wrong!

Of the following, which is not a requirement for marking on a transformer’s nameplate?

Correct! Wrong!

Which of the following is a requirement for electrically heated floors in bathrooms, kitchens, and in hydromassage bathtub locations?

Correct! Wrong!

Lighting systems for fountains, pools, spas, and similar locations must be installed __________ or more horizontally from the nearest water’s edge, unless Article 680 permits otherwise.

Correct! Wrong!

On portable generators manufactured before ____________, listed cord sets or adapters incorporating listed GFCI protection are allowed to be used to meet the GFCI requirement.

Correct! Wrong!

Temporary electric power and lighting installations for holiday decorative lighting and similar purposes is allowed for a maximum of:

Correct! Wrong!

Where the available short-circuit current for the battery bank on a PV system exceeds the interrupting or ____________ ratings of the equipment it supplies, a listed current-limiting overcurrent device must be installed.

Correct! Wrong!

Tap conductors on a common dc grounding electrode conductor of a PV system must be sized in compliance with 250.166. The connection between the common grounding electrode and the tap conductor must be such that the common grounding electrode conductor is:___________

Correct! Wrong!

Power-limited fire alarm cable must have a moisture-impervious metal sheath or be listed for the purpose if they are used in what kind of location?

Correct! Wrong!

What must be done with approved ratings, to maintain the fire-resistance rating, to openings around penetrations of raceways for communications and optical fiber cables through fire-resistant-rated ceilings, floors, partitions, and walls?

Correct! Wrong!

When are Class 1 circuit conductor and power-supply conductors are allowed to be in the same cable, enclosure, or raceway?

Correct! Wrong!

It is not required to list or mark community antenna television and radio system coaxial cables if the cable is not more than ______ from where the cable enters the building from the outside to where it is terminated at a grounding block.

Correct! Wrong!

During lightning events, limiting the length of the primary protector grounding conductors for communications circuits assists in reducing voltage between the buildings communications systems and:___________

Correct! Wrong!

What type of protection is needed for the grounding electrode conductor for an antenna if it is subject to physical damage?

Correct! Wrong!

What is the maximum cross-sectional value that conduit nipples under 24 inches long may be filled?

Correct! Wrong!

If more than 2 conductors are used in a tube of EMT conduit, total interior area that can be filled is no more than ________ percent.

Correct! Wrong!

Given the following information, what is the maximum approximate distance a single-phase, 240-volt, 42 ampere load can be located from a panelboard? * copper conductors – K = 12.9 * size 8 AWG THWN/THHN conductors are used * Limit voltage drop to 3%

Correct! Wrong!

100 Question Timed Free Electrician Certification Exam