IMPORTANT INFORMATION: If you are an existing ECC Student,

YOU ARE IN THE RIGHT PLACE!

Welcome to our new Continued Education online classroom!

This new classroom completely replaces our previous online study environment. It features:

  • Improved and more intuitive functionality.
  • Many new courses, Including 2017 NEC Code Courses and California Title 24.
  • Compatability with all devices with internet access.
  • Also works great on your smartphone!

If you are already signed up and need to continue your hours: Select Classroom Login on the right side of the site navigation and type in either your Username OR Email Address. Your login information has not changed, and your completed hours should still be present. We have made every effort to ensure a smooth transition, but should you find anything to be in error please call us immediately at 866-685-8564 between 7 am to 10 pm Mon – Fri.

If you are a returning student and need to start your lessons: click the person icon next to the shopping cart to log into your account. Your username and password have not changed. Once logged in you can select orders and then select the (Go Shop) Button choose your course by adding it to the cart.

If you have forgotten your login information, you can reset it: Just click here and enter the username or email address associated with your old account and you will recieve an email allowing you to reset your password.

New Students: Click the Our Courses button in the site navigation and add the product you need to the cart to begin the process of creating your account.

Contractor's Licensing Consultants - Image of Hardhat

1-866-685-8564

CALL US NOW

​for a free consultation!

  • Our Courses
  • Why Use TLC?
  • FAQ
  • Classroom Login
  • Cart
  • Account

Select a program below or give us a call today for a free consultation @ 1-866-685-8564

Continued Education Programs

  • California - 32 Hour Continuing Education
  • California - 1 Hour Continuing Education

Exam Preparation Programs

  • Alabama Electrician Exam
  • Alaska Electrician Exam
  • Arizona C-11 Electrician Exam
  • Arkansas Electrician Exam
  • California Journeyman Electrician Exam
  • Colorado Electrician Exam
  • Connecticut Electrician Exam
  • Florida Journeyman Electrician Exam
  • Idaho Electrician Exam
  • Iowa Electrician Exam
  • Kansas Journeyman Electrician Exam
  • Kentucky Electrician Exam
  • Maine Electrician Exam
  • Maryland Master Electrician Exam
  • Massachusetts Electrician Exam
  • Michigan Electrician Exam
  • Missouri Journeyman Electrician Exam
  • Montana Electrician Exam
  • New Mexico Electrician Exam
  • Nevada Journeyman Electrician Exam
  • Oklahoma Journeyman Electrician Exam
  • South Dakota Electrician Exam
  • Tennessee Electrician Exam
  • Texas Electrician Exam
  • Utah Electrician Exam
  • Virginia Journeyman Electrician Exam
  • Washington Electrician Exam
  • Wyoming Electrician Exam

The power sources for limited power circuits for listed audio/ video information technology (equipment) and listed industrial equipment shall have a label indicating the maximum __________and __________output for each connection point.

T/F: Paint, plaster, cleaners, abrasives, corrosive residues, or other contaminants may result in an undetermined alteration of optical fiber cable properties.

PLFA cables installed as wiring within buildings shall be listed as being resistant to the spread of fire and have a voltage rating of not less than __________ volts and a temperature rating of not less than __________

Power-limited fire alarm cables shall be permitted to be installed in __________ selected in accordance with Table 800.154(c), listed in accordance with the provisions of 800.182, and installed in accordance with 800.110(C) and 800.113.

Types CL2P and CL3P plenum cable shall be __________for use in ducts, plenums, and other space for environmental air and shall be listed as having adequate fire-resistant and low-smoke producing characteristics.

The conductors that carry power Class 2 and Class 3 data circuits shall be __________. The current in the power circuit shall not exceed the current limitation of the connectors.

T/F: Class 2, Class 3, and Type PLTC cables shall be permitted to be installed in plenum cable routing assemblies, riser cable routing assemblies, and general-purpose cable routing assemblies selected in accordance with Table 800.154(c), listed in accordance with the provisions of 800.182, and installed in accordance with 800.110(C) and 800.113

A __________ means shall be provided to disconnect an interactive system from all wiring systems including power systems, energy storage systems, and utilization equipment and its associated premises wiring.

Article 725 Class 1, Class 2, and Class 3 Remote Control, Signaling, and Power-Limited Circuits, covers __________.

A device connected on the load side of a branch circuit over-current protective device that transfers only emergency lighting loads from the normal supply to an emergency supply is referred to as a __________?

Better Business Bureau Logo - Rating A+
Protect your company, your workforce, and
your bottom line

Disclaimer – Privacy Policy – Conditions of Use

© 2019 Thompson Learning Co.